Jual Water Meter Zenner Tipe WPD Size 3 Inch
Informasi Produk
Spesifikasi :
Water Meter Zenner
Type : WPD
Meter Size : 3 Inch ( DN 80 mm )
-Nominal diameter ( DN 80mm )
-Permanent flowrate : 100 m³ / h
-Attainable measuring range : R315H125V
-Standard measuring range 1 : R160H63V
-Overload flowrate : 125 M³ / H
-Minimum flowrate 2 : 0.63 / 1.59 M³ / H
-Transitional flowrate 2 : 1.0 / 2.54 M³ / H
-Start-up flow rate : 0.11 M³ / H
-Display range
min. 1 : 0.5
max. m³ : 999.999
-Temperature range
min. -, °C : 0.1-50
-Operating Pressure
Map, bar : 0.3-16
-Pulse Value reed
Map -, l/Pulse : 100
-Pulse Value modulator disc
Map -, l/Pulse : 10
-Pressure loss class at Q3
P,Bar : 0.40
-Mechanical environmental condition :
p-, bar - : M2
-Climatic condition 4
p-, °C : 5-55
-Flow profile sensitivity
p- °C- : U0/D0
Tersedia dan siap dikirim
Jual Water Meter Zenner Tipe WPD Size 3 Inch
WATER METER ZENNER
WPD / WPHD
Woltman meter with impeller axis arranged in parallel to the flow direction
the bulk water meter WPD / WPHD is used to record high flows in drinking water distribution and in industry, with low pressure loss and a predominantly constant flow profile at the same time.
the meter is equipped with a 6- roller dry dial register ( IP68 ) and a modulator disc. This enables electronic, reaction-free scaning and is the basis for remote reading of the meter data via radio with Lorawan or Wm-Bus. A combined M-Bus / pulse module is also posible.
A mechanical pulse can also be connected in parallel.
performance characteristics at a glance
-Woltman parallel type
-All materials, which are used in the drinking water section, comply with the required standards, guidelines and the current German drinking water approval ( other country-specificdrinking water approvalson request )
-WPD ( DN 40-150 ), WPHD ( DN 200-300 )
-For horizontal and vertical installation
-Replaceable MID-compliant metrological unit
-Highest precision and reliability even in case of low flow rates
-Flood-proof hermetically sealed glass / copper register ( IP68 )
-Low starting flow and high overload security
-Wide measuring range, low pressure loss
-Hydraulic bearing relief
-Durable measuring stability
-Swirl- reducing inlet
-No straight inlet or outlet needed ( U0/D0) according to OIML R49 and DIN EN ISO 4064
-Optimally equipped for remote readout
-Register rota table 355°
-Operating pressure MAP 16 ( optionally MAP 10 )
-Approved in accordance with MID and OIML
-Compatible with Data longger
APPLICATION
-For the consumption measurement of cold and clean drinking water or service water up to 50° C.
-For measuring high flows
AMR OPTIONS
-Can be combined with stationary GSM system
-Retrofit table with EDC module ( Electronic Data Cap-ture );
EDC-LPWAN radio module (868 MHz ) for loRaWAN
EDC-Wireless M-Bus radio module ( 868 MHz )
EDC-combined M- Bus and Pulse module